APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5166 Issued:1978-01-17
Revised:2012-08-17
Style 5166 Single conductor with other than extruded insulation.

Rating105 deg C, 600 Vac, Horizontal Flame.
Conductor20 AWG - 4 AWG consisting of 38-30 AWG stranding, tinned or bare copper. Length of lay per requirements for Type ST Cord.
InsulationConsists of an inner closely woven non-extruded Polyester braid with a Polyester tape, approximately 1.0 mil thick, minimum 0.5 inch wide applied with a minimum 50% overlap over inner braid. Over this assembly an outer closely woven non-extruded Polyester braid is applied.
AssemblyInsulated single conductor.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseLead wire within Hermetic Motors where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.