Rating | 450 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 24 AWG - 4/0 AWG, solid or stranded in sizes 24 - 8 AWG, larger sizes stranded only. |
|
Insulation | FIBERGLASS or MICA, 17 mils min average, 15 mils minimum at any point. |
|
Braid | For conductor 24-12 AWG, 5 mils min avg of inner glass braid, 5 mils min avg of total mica tape layers and 7 mils min avg of outer glass braid; 11-4 AWG, 10 mils avg, 10 mils avg and 15 mils avg as described; 3-4/0 AWG, 10 mils avg, 13 mils avg and 20 mils avg as described. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of similar high-temperature equipment where not subjected to repeated flexing and protected from mechanical abuse. (The acceptability, including current-carrying capacity, has been determined by Underwriters Laboratories Inc.) |
|