APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5170 Issued:1978-12-19
Revised:2012-07-22
Style 5170 Single conductor with other-than-extruded insulation

Rating125 deg C, 600 Vac.
Conductor22 AWG - 4 AWG consisting of 38-30 AWG stranding, length of lay per requirements for Type ST Cord.
InsulationNonextruded Polyethylene Terephthalate tape, minimum average 0.5 mil thick, applied with half lap between inner and outer closely woven polyethylene terephthalate fiber or polyester braids, alternate - outer braid may be Aramid fiber.
AssemblyInsulated single conductor.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseLead wire within Hermetically Sealed Motors where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.