APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5180 Issued:1980-03-13
Revised:2011-12-02
Style 5180 Single Conductor with Other-than-Extruded insulation.

Rating250 deg C, 300 Vac.
Conductor24 AWG - 2 AWG solid or stranded round.
InsulationSkived PTFE tape
Conductor SizeMinimum thickness at any point
24-18 AWG4 mils
16-8 AWG8 mils
6-2 AWG12 mils
CoveringInner Covering - Two layers of glass serve over the insulation.
Conductor SizeMinimum thickness at any point
24-8 AWG10 mils
6-2 AWG15mils
Outer Covering - Treated Glass Braid or Treated Polyaramid Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024