|
| Rating | 125 deg C, 600 Vac. |
|
| Conductor | 20 AWG - 2 AWG, consisting of 30-38 AWG stranding. Length of lay per requirements for Type ST Cord. May employ rope lay stranding in all sizes per UL 62 except the maximum lay of members shall be 1 inch for 20 and 19 AWG, sizes 2 inches for 18-11 AWG, 2-1/2 inches for 10 and 9 AWG. |
|
| Inner Braid | Closely woven Polyester braid. |
|
| Insulation | Consists of inner Teflon tapes and outer PETP tape. |
| Conductor size | Minimum average wall of Teflon tapes | Minimum average wall of PETP tape |
| 20 - 10 AWG | 2 mils | 0.5 mil |
| 8 AWG | 6 mils | 2 mils |
| 6 - 4 AWG | 9 mils | 3 mils |
| 2 AWG | 15 mils | 3 mils |
| Minimum overlap of tapes shall be 25 percent of tape width. |
|
| Assembly | Insulated single conductor. Conductor is covered with Inner Braid, Insulation and Outer Braid. |
|
| Outer Braid | Closely woven Polyester braid. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Lead wire within hermetic motors where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|