Rating | 105 deg C, 600 Vac. |
|
Conductor | 20 AWG - 4 AWG, 38-30 AWG stranding, Length of Lay per requirements for type ST Cord, May employ rope lay stranding in all sizes per UL 62 except the maximum lay of members shall be 1 inch for 20 and 19 AWG sizes, 2 inches for 18-11 AWG, 2 1/2 inches for 10 and 9 AWG. |
|
Insulation | Non-extruded PETP tape, minimum 0.8 mil thickness, applied over the conductor with halt lap. |
|
Inner Covering | Non-extruded PETP Yarn. One layer spiral wrapped or braid over insulation. |
|
Outer Covering | Non-extruded PETP Yarn. One layer braided over above covering. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Lead wire within Hermetic Motors where the acceptability of the combination is to be determined by Underwriters Laboratories, Inc. |
|