APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5196 Issued:1982-09-16
Revised:2019-07-16
Style 5196 Glass Braided Wire.

Rating250 deg C, 600 Vac, Horizontal Flame.
Conductor24 AWG - 4/0 AWG solid or stranded round.
InsulationNon-extruded PTFE, TFE tape, 24-8 AWG, 15 mils at any point, 6-2 AWG, 20 mils at any point, 1-4/0 AWG, 25 mils at any point.
CoveringInner Covering - Non-extruded Glass serve over the insulation. 10 mils min at any point for 24-8 AWG, 15 mils min at any point for 6-2 AWG, 20 mils min at any point for 1-4/0 AWG. Outer Covering - No-extruded Treated Glass or Polyaramid Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024