APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5197 Issued:1982-12-07
Revised:2012-01-13
Style 5197 Multiple-conductor cable using non-integral jacket

Rating80 deg C, Voltage not applicable, VW-1 flame.
ConductorGlass fiber core, 4 mils min, 10 mils max diam.
BufferSR - SILICONE, 3 mils min average.
AssemblyTwo or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. For composite optic core, may be covered with silicone resin coating and/or nylon covering. Composite core 4 mils min, 50 mils max diameter. Reinforcement Filler - (Optional) Material not specified.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024