APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5206 Issued:1983-02-25
Revised:2019-11-07
Style 5206 Multiple conductor cable using non-integral jacket.

Rating80 deg C, 600 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
ConductorFiber optic. 4 mils minimum, 6 mils max diam.
BufferLabeled or complying with manufacturer's AWM procedure, 10 mils min average, 9 mils minimum at any point. Manufacturer shall maintain a complete description of each assembly.
AssemblyOne or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. For composite optic core - One or more, glass fiber core covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional.
ShieldOptional.
CoveringOuter Covering - (Optional) Extruded PVC, 5 mil min.
JacketPVC
dia in inches
0.700 or less60 mils min average48 mils minimum at any point
0.701-1.000 dia80 avg64 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024