APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5207 Issued:1983-02-25
Revised:2012-03-30
Style 5207 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 600 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
Fiber OpticOne or more glass fiber cores, covered with silicone resin or covering, fillers optional, 4 mils minimum diameter, 6 mils maximum diameter.
ConductorLabeled or complies with manufacturer's procedure. Manufacturer shall maintain a complete description of each assembly.
AssemblyOne or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. Cmposite optic core - One or more, glass fiber core covered with silicone resin or covering. Fillers optional.
ShieldOptional.
CoveringOuter Covering - (Optional) Extruded PVC, 5 mils minimum thickness.
JacketExtruded PVC
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less6048
0.701-1.5008064
1.501-2.50011088
2.501 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.