APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5208 Issued:1983-02-25
Revised:2012-03-28
Style 5208 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 Flame.
BufferLabeled or complies with manufacturer's procedure. Manufacturer shall maintain a complete description of each assembly. One or more, glass fiber core, 4 mils mininimum diameter, 6 mils maximum diameter. May be covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional.
AssemblyOne or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified.
ShieldOptional.
CoveringOuter - Optional PVC, 5 mils minimum thickness.
JacketExtruded PVC
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0006048
1.001-1.5008064
1.501-2.50011088
2.501 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.