Rating | 80 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 Flame. |
|
Buffer | Labeled or complies with manufacturer's procedure. Manufacturer shall maintain a complete description of each assembly. One or more, glass fiber core, 4 mils mininimum diameter, 6 mils maximum diameter. May be covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional. |
|
Assembly | One or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. |
|
Shield | Optional. |
|
Covering | Outer - Optional PVC, 5 mils minimum thickness. |
|
Jacket | Extruded PVC |
| Diameter of core assembly under jacket (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 60 | 48 |
| 1.001-1.500 | 80 | 64 |
| 1.501-2.500 | 110 | 88 |
| 2.501 and larger | 140 | 112 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring or External Interconnection of Electronic Equipment. |
|