APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5209 Issued:1983-02-25
Revised:2012-03-15
Style 5209 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
ConductorFiber Optic. 4 mils minimum diameter, 6 mils maximum diameter.
BufferLabeled or complies with manufacturer's procedure. Manufacturer shall maintain a complete description of each assembly.
AssemblyOne or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. For composite fiber optic core - One or more glass fiber core covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional.
ShieldOptional.
CoveringOuter Covering - (Optional) extruded PVC, 5 mils minimum average thickness.
JacketExtruded PVC
Diameter of core assembly under jacket (inches) ¿Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0006048
1.001-1.5008064
1.501-2.50011088
2.501 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024