APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5210 Issued:1983-02-25
Revised:2012-01-11
Style 5210 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 30 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
ConductorFiber Optic. 4 mils minimum diameter, 6 mils maximum diameter.
BufferOptional - SR or PE coating.
CoveringInner. Optional - Nylon or PE.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
AssemblyOne or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. For composite optic core - One or more glass fiber core covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional. Manufacturer shall intain a complete description of each assembly.
ShieldOptional.
CoveringOuter. Optional - PVC, 5 mils minimum thickness at any point.
JacketExtruded PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch60 mils48 mils
1.001-1.500 inches80 mils64 mils
1.501-2.500 inches110 mils88 mils
2.501 inches and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Class 2 Circuits of Electronic Equipment.