APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5211 Issued:1983-02-25
Revised:2019-11-07
Style 5211 Single or Multiple-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
Composite Optic Core, Coat & CoverOne or more, glass fiber core, 4 mils min, 6 mils max diam. May be covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional.
Insulated ConductorLabeled or complies with manufacturer's procedure with min rating of 105 deg C, 30 V. Manufacturer shall maintain a complete description of each assembly.
AssemblyOne or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified.
CoveringOuter Covering - (Optional) PVC, 5 mil min.
ShieldOptional.
JacketPVC
dia in inches
0.700 or less30 mils min average23 mils minimum at any point
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Class 2 Circuits of Electronic Equipment.