APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5215 Issued:1983-06-08
Revised:2012-04-26
Style 5215 Single conductor with other-than-extruded insulation.

Rating250 deg C, 300 Vac, Horizontal flame.
Conductor24 AWG - 2 AWG solid or stranded.
InsulationExtruded PTFE tape, Glass fiber wrap or felted Aramid fibers. Conductor size of 24-18 AWG, TFE tape-4 mils min at any point, Double Glass Fiber Wrap-8 mils min at nay point, Felt Aramid Fibers-4 mils min at any point; 16-8 AWG, TFE-8 mils, Glass Fiber-8 mils, Aramid-4 mils; 6-2 AWG, TFE-12 mils, Glass Fiber-8 mils, Aramid-6 mils.
CoveringTreated glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.