Rating | 105 deg C, 300 Vac, Horizontal flame, Oil Res 60 or 80 deg C (optional), Gasoline Resist (opt) |
|
Conductor | 36 AWG - 6 AWG solid or stranded round, tinned, silver plated, or nickel coated copper, nickel conductor, silver plated zirconium copper alloy, silver plated cadmium chrome copper alloy, silver plated cadmium bronze copper alloy, or silver plated copper-clad steel. |
|
Insulation | Bonded, spiral wrapped PTFE, TFE tape |
| 36-20 AWG conductor size | 5.5 mils min average | 5 mils minimum at any point |
| 19-16 AWG | 8 avg | 7 min |
| 15-10 AWG | 13 avg | 12 min |
| 9-6 AWG | 20 avg | 18 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. Tag may state: "Suitable for immersion in gasoline; gasoline vapor; and 60 degrees C or 80 degrees C in oil". |
|