APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5240 Issued:1984-05-14
Revised:2011-12-29
Style 5240 Fiber Optic

Rating80 deg C, voltage rating not applicable, VW-1 flame.
ConductorGlass fiber, 3 mils min, 12 mils max, dia
BufferCOATING, Optional, Resin buffer.
CoveringOptional. Material not specified.
JacketSingle conductor - Thermoplastic PVC 20 mils min at any point. Multiconductor - two conductors assembly jacket thickness 8 mils min at any point, and four conductors assembly jacket thickness 20 mils min at any point.
Misc.Reinforcement Filler - (Optional) Material not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or External Interconnection of Electronic Equipment.