APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5241 Issued:1984-06-25
Revised:2012-04-27
Style 5241 Fiber Optic with Non-integral jacket

Rating80 deg C, voltage rating not applicable, VW-1 flame.
ConductorGlass fiber, 3 mils min, 12 mils max, dia.
BufferCOATING, Optional, Silicone or Acrylate Resin. 3 mils min average.
CoveringOptional, ETFE, Nylon, Polyester.
Misc.Reinforcement Filler - (Optional) Material not specified.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024