APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5259 Issued:1986-04-16
Revised:2019-05-12
Style 5259 Single conductor with other than extruded insulation

Rating250 deg C, 600 Vac, Horizontal Flame.
Conductor22 AWG - 4/0 AWG, Solid or Stranded Round.
InsulationNon-Extruded Mica Tape and Non-Extruded PTFE Tape
Conductor AWG Sizemils minimum at any point for total Mica tape layersmils minimum at any point for PTFE
22-12125
10-6205
4-4/03010
BraidOverall non-extruded treated glass braid, 7.5 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024