APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5265 Issued:1986-06-17
Revised:2012-08-20
Style 5265 Multiple-conductor cable using non-integral jacket

Rating90 deg C, voltage rating not applicable, VW-1 Flame.
ConductorPlastic fiber, 3 mils minimum diameter, 75 mils maximum diameter
CoatingOptional - Silicone resin, 3 mils minimum average thickness
AssemblySingle or multiple, up to 100, bunched together. Two through ten fiber core units may be laid parallel (SPT style construction). Fiber cores consist of fiber, coating, covering, reinforcement filler.
CoveringOptional - Thermoplastic
Reinforcement FillerOptional - Material not specified
JacketExtruded PVC, 7 mils minimum average thickness, 5 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnect of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024