APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5272 Issued:1986-11-07
Revised:2012-04-18
Style 5272 Single-conductor cable using non-integral jacket

Rating60 deg C, voltage rating not applicable, Horizontal flame.
ConductorFiber Optic. Glass fiber, 3 mils min. 18.5 mils max., diam.
CoatingOptional, silicone resin.
CoveringOptional, thermoplastic material.
CoveringOptional, PVC, 2 mils min.
AssemblySingle, two fiber core units may be parallel. Barrier layer and fillers may be employed, material not specified.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point.
Misc.Both inner and outer reinforcement filler - Optional, material not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024