APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5273 Issued:1986-11-07
Revised:2012-04-26
Style 5273 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, voltage rating not applicable, Horizontal flame.
Optic CoreGlass fiber, 3 mils minimum, 18.5 mils maximum diameter.
CoatingOptional - silicone resin.
CoveringOptional, thermoplastic material.
AssemblyMultiple, up to 100 bunched together. Two fiber core units may be parallel. Barrier layer and fillers may be employed, material not specified.
Reinforcement FillerOptional - Material not specified.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024