APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5275 Issued:1986-11-07
Revised:2012-04-16
Style 5275 Single conductor with other-than-extruded insulation.

Rating80 deg C, voltage rating not applicable, Horizontal flame.
ConductorOptic Core - Glass fiber, 3 mils minimum, 18.5 mils maximum diameter.
BufferCoating, Optional, silicone resin. 3 mils minimum average thickness.
AssemblyMultiple, up to 100 bunched together. Two fiber core units may be parallel. Barrier layer and fillers may be employed, material not specified. Reinforcement filler, optional.
CoveringInner - Optional, thermoplastic material. Outer - Optional, Extruded PVC, 2 mils minimum thickness.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024