| Rating | 60 deg C, voltage rating not applicable, VW-1 flame. |
|
| Conductor | Optic Core- Glass fiber, 1.3 mils min, 12 mils max, dia. |
|
| Buffer | Optional. Resin buffer. |
|
| Assembly | One to four cores, reinforcement Filler - Optional, material not specified, laid parallel with an overall jacket |
|
| Covering | Optional. material not specified. |
|
| Jacket | PVC, 30 mils min average, 24 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring or external interconnection of electronic equipment. |
|