APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5288 Issued:1988-02-03
Revised:2012-07-18
Style 5288 Single conductor with other than extruded insulation

Rating250 deg C, 600 Vac.
Conductor24 AWG - 4 AWG, Solid or Stranded Round, Nickel or Nickel-clad copper, or Nickel-clad iron.
InsulationFor Sizes 24-8 AWG: Non-Extruded PTFE tape; 15 mil minimum average, 13 mil minimum at any point with two layers of Cequin IF 10 mil minimum average, 8 mil minimum at any point. For Sizes 6-4 AWG: Non-Extruded PTFE tape; 20 mil minimum average, 17 mil minimum at any point with two layers of Cequin IF, 15 mil minimum average, 13 mil minimum at any point.
BraidTreated Glass Braid.
JacketOptional. Extruded PFA, 5 mils at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024