APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5296 Issued:1988-11-11
Revised:2012-03-15
Style 5296 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, voltage not applicable, VW-1 flame.
ConductorOptic Cores - Glass fiber, 2 mils minimum diameter, 12 mils maximum diameter.
BufferCoating, Optional, Thermoplastic, 3 mils minimum average thickness.
Fillers/SeparatorBoth inner and outer filler - Optional, material not specified. Separator - Optional, material not specified.
CoveringInner - Extruded Nylon, 12 mils minimum average thickness, 10 mils minimum thickness at any point. Outer - Extruded PVC, 18 mils minimum average thickness, 16 mils minimum thickness at any point.
AssemblyTwo fiber cores and three reinforcement cores cabled together. Fiber cores - optional coating, inner covering, optional fillers and outer covering. Reinforcement - Steel core reinforcement members employing 15 mils minimum thickness, 30 mils maximum thickness coverings, material not specified. For overall cable - built with optional filler, optional separator and jacket.
JacketExtruded PVC, 31 mils minimum average thickness, 25 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024