Rating | 105 deg C, voltage not applicable, VW-1 flame. |
|
Optic Cores | Glass fiber, 2 mils minimum, 12 mils maximum. |
|
Coating | Optional, thermoplastic. |
|
Covering | Nylon, 12 mils minimum average, 10 mils minimum at any point. |
|
Fillers | Optional, material not specified. |
|
Jacket | PVC, Class 43, 31 mils min average, 25 mils minimum at any point. |
|
Reinforcement Cores | Steel core reinforcement members, 18 AWG. |
|
Jacket | PVC, Class 43, 31 mils min average, 25 mils minimum at any point. |
|
Assembly | Two jacketed fiber optic cores bonded together. Each of the jacketed fiber optic cores are then bonded to a jacketed, reinforcement member to form a flat cable. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|