Rating | 80 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 flame. |
|
Conductor | Fiber Optic. Optic Core - One or more, plastic fiber core. May use mixed AWG sizes. labeled or complies with manufacturers AWM procedure. |
|
Buffer | Labeled or complies with manufacturer's procedure. |
|
Assembly | One or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. Singles or twisted pairs may be laid parallel to form a flat, oval and round cable. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional. |
|
Covering | Outer - (Optional) PVC 5 mils min. |
|
Jacket | PVC |
| dia in inches |
| 0.700 or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 60 avg | 48 min |
| 1.001-1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring or External Wiring |
|