APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5319 Issued:1992-01-13
Revised:2019-11-07
Style 5319 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
ConductorFiber Optic. Optic Core - One or more, plastic fiber core. May use mixed AWG sizes. labeled or complies with manufacturers AWM procedure.
BufferLabeled or complies with manufacturer's procedure.
AssemblyOne or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. Singles or twisted pairs may be laid parallel to form a flat, oval and round cable. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOuter - (Optional) PVC 5 mils min.
JacketPVC
dia in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Wiring