APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5322 Issued:1992-07-14
Revised:2019-11-07
Style 5322 Fiber Optic with Single or multiple conductor with extruded insulation

Rating80 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
BufferFiber optic and copper conductors - Labeled or complies with manufacturer's procedure. Manufacturer shall maintain a complete description of each assembly.
ShieldOuter - (Optional)PVC, 5 mils minimum thickness average.
CoveringOptional.
JacketPVC
dia of cable under jacket in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501 dia and larger110 avg88 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024