Rating | 450 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 24 AWG - 4 AWG, solid or stranded. |
|
Insulation and Braid | Non-extruded Mica with Glass Braid. |
| | Min Avg wall of | Min Avg thickness of |
| | Composite Mica Glass | Glass Braid Treated with Silicone Varnish or TFE Finish |
| AWG Size | (mils) | (mils) |
| 24-12 | 17 | 5 |
| 11-4 | 20 | 10 |
|
Shield | Optional. stainless steel, alloy 304, applied as a braid over the treated glass braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Wiring of ovens or similar high-temperature equipment where protected from mechanical abuse and where the acceptability, including current-carrying capacity, has been determined by Underwriters Laboratories Inc. |
|