APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5335 Issued:1993-09-14
Revised:2012-04-09
Style 5335 Single or multiple conductor with non-extruded insulation

Rating450 deg C, 600 Vac, Horizontal flame.
Conductor22 AWG - 4/0 AWG. Solid or stranded in sizes 22-8 AWG; larger sizes stranded only.
InsulationMica with Glass Braid
MaterialConductor sizeMinimum average thickness
Mica22-12 AWG23 mils
Mica11-4 AWG27 mils
Mica2-4/0 AWG32 mils
Glass braid treated with silicone varnish or TFE finish22-12 AWG5 mils
Glass braid treated with silicone varnish or TFE finish11-4 AWG10 mils
Glass braid treated with silicone varnish or TFE finish3-4/0 AWG15 mils
AssemblyOptional. Two or more conductors described above, may be cabled together with a max O.D. of 1.500 inches. A mica glass binder and/or fiberglass fillers may be employed. The assembly has an overall treated glass braid.
Shield(Optional) Nos. 36-30 AWG Type "A" Nickel or 27% minimum nickel coated copper or nickel-chromium-iron or stainless steel, 304.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where protected from mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2024