Rating | 450 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 22 AWG - 4/0 AWG. Solid or stranded in sizes 22-8 AWG; larger sizes stranded only. |
|
Insulation | Mica with Glass Braid |
| Material | Conductor size | Minimum average thickness |
| Mica | 22-12 AWG | 23 mils |
| Mica | 11-4 AWG | 27 mils |
| Mica | 2-4/0 AWG | 32 mils |
| Glass braid treated with silicone varnish or TFE finish | 22-12 AWG | 5 mils |
| Glass braid treated with silicone varnish or TFE finish | 11-4 AWG | 10 mils |
| Glass braid treated with silicone varnish or TFE finish | 3-4/0 AWG | 15 mils |
|
Assembly | Optional. Two or more conductors described above, may be cabled together with a max O.D. of 1.500 inches. A mica glass binder and/or fiberglass fillers may be employed. The assembly has an overall treated glass braid. |
|
Shield | (Optional) Nos. 36-30 AWG Type "A" Nickel or 27% minimum nickel coated copper or nickel-chromium-iron or stainless steel, 304. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring where protected from mechanical abuse. |
|