APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5353 Issued:1998-11-19
Revised:2012-03-19
Style 5353 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, Voltage not applicable to Fiber Optic, Horizontal flame.
Fiber Optic CoreGlass fiber may be 10 mils minimum diameter at any point, covered with a buffer or covering.
BufferExtruded TPU, 3 mils minimum average thickness.
AssemblyAn optic core with optional reinforcement, optional inner shield, covering, optional outer shield and overall jacket.
ShieldInner and outer shield are optional.
CoveringExtruded Thermoplastic, 2 mils minimum thickness at any point.
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
Misc.Reinforcement Filler - (Optional) Material not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.