APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5354 Issued:1999-02-19
Revised:2012-03-29
Style 5354 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 30Vac, voltage not applicable to Fiber Optic, Horizontal flame.
ConductorGlass fiber may be 10 mils minimum diameter at any point covered with a buffer or covering.
BufferCoating, 2 mils minimum average thickness, material not defined.
AssemblyA glass fiber optic core with optional reinforcement filler, inner covering, optional inner shield, outer covering, optional outer shield and overall jacket.
ShieldInner and outer shield are optional.
CoveringInner and outer covering - Thermoplastic, 2 mils minimum thickness at any point.
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
Misc.Reinforcement Filler - (Optional) Material not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment or External Interconnection where not routed along walls, floors or other abuse areas.