APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5355 Issued:1999-04-08
Revised:2012-03-19
Style 5355 Bonded Non-Extruded Flat Ribbon Cable

Rating80 deg C, 60 Vac, Horizontal flame.
Conductor40 AWG - 12 AWG flat or round, material not specified.
InsulationPET, PETP film, 0.4 mils minimum average thickness. PETP (polyester) film bonded each side with 0.5 mils thick polyester adhesive, 10 mils minimum edge width and 3 mils minimum distance between conductors.
AssemblyOne to 150 conductors laid straight or irregular, parallel in one plane.
Drain WireOptional.
ShieldOptional. Metal faced polymeric tape.
CoveringOptional. Material not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.