Rating | 200 or 450 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 4/0 AWG, solid or stranded in sizes 26-8 AWG; larger sizes stranded only. |
|
Insulation | Mica tape with Glass Braid treated with Silicone varnish or PTFE finish. |
| Conductor size | Minimum average thickness of total Mica tape layers | Minimum average thickness of Glass Braid treated with Silicone varnish or PTFE finish layer |
| 30-12 AWG | 16 mils | 7 mils |
| 11-4 AWG | 20 mils | 15 mils |
| 3-4/0 AWG | 25 mils | 20 mils |
|
Shield | Optional, 36-30 AWG Type "A" Nickel or 27 percent minimum nickel coated copper. |
|
Assembly | Optional, two or more insulated conductors described above, may be cabled together with a max O.D. of 1.500 inches. A mica glass binder and/or fiberglass fillers may be employed. |
|
Covering | Optional, treated glass braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring where not subjected to repeated flexing and protected from mechanical abuse, and where the acceptability, including current-carrying capacity, has been determined by Underwriters Laboratories Inc. |
|