APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5359 Issued:1999-07-19
Revised:2019-05-13
Style 5359 Single or multi-conductor with other-than extruded Insulation

Rating200 or 450 deg C, 600 Vac, Horizontal flame.
Conductor30 AWG - 4/0 AWG, solid or stranded in sizes 26-8 AWG; larger sizes stranded only.
InsulationMica tape with Glass Braid treated with Silicone varnish or PTFE finish.
Conductor sizeMinimum average thickness of total Mica tape layersMinimum average thickness of Glass Braid treated with Silicone varnish or PTFE finish layer
30-12 AWG16 mils7 mils
11-4 AWG20 mils15 mils
3-4/0 AWG25 mils20 mils
ShieldOptional, 36-30 AWG Type "A" Nickel or 27 percent minimum nickel coated copper.
AssemblyOptional, two or more insulated conductors described above, may be cabled together with a max O.D. of 1.500 inches. A mica glass binder and/or fiberglass fillers may be employed.
CoveringOptional, treated glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to repeated flexing and protected from mechanical abuse, and where the acceptability, including current-carrying capacity, has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024