Rating | 200 or 450 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 4/0 AWG. Solid or stranded in Sizes 26-8 AWG; larger sizes stranded only. |
|
Insulation | Nonextruded Mica tape with Glass Braid |
| AWG size | Min Avg. thickness of total Mica tape layers (mils) | Min Avg. thickness of Glass braid treated with Silicone Varnish or TFE Finish (mils) |
| 30-12 | 12 | 7 |
| 11-8 | 16 | 7 |
| 7-4 | 20 | 15 |
| 3-4/0 | 25 | 20 |
|
Shield | Optional. 36-30 AWG Type "A" Nickel or 27 percent minimum nickel coated copper. |
|
Assembly | Single conductor or two or more conductors described above, may be cabled together with a max O.D. of 1.500 inches. A Mica glass binder and/or fiberglass fillers may be employed. The assembly may have an overall treated glass braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring where not subjected to repeated flexing and protected from mechanical abuse, and where the acceptability, including current-carrying capacity, has been determined by Underwriters Laboratories Inc. |
|