APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5360 Issued:1999-07-19
Revised:2019-05-13
Style 5360 Single conductor with other-than-extruded insulation.

Rating200 or 450 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 4/0 AWG. Solid or stranded in Sizes 26-8 AWG; larger sizes stranded only.
InsulationNonextruded Mica tape with Glass Braid
AWG sizeMin Avg. thickness of total Mica tape layers (mils)Min Avg. thickness of Glass braid treated with Silicone Varnish or TFE Finish (mils)
30-12127
11-8167
7-42015
3-4/02520
ShieldOptional. 36-30 AWG Type "A" Nickel or 27 percent minimum nickel coated copper.
AssemblySingle conductor or two or more conductors described above, may be cabled together with a max O.D. of 1.500 inches. A Mica glass binder and/or fiberglass fillers may be employed. The assembly may have an overall treated glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to repeated flexing and protected from mechanical abuse, and where the acceptability, including current-carrying capacity, has been determined by Underwriters Laboratories Inc.