APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5363 Issued:1999-07-21
Revised:2012-04-26
Style 5363 Single conductor with other-than-extruded insulation

Rating90 deg C, voltage rating not applicable, Horizontal flame.
ConductorAcrylate coated glass fibers laminated between acrylate film, 14 mils maximum minor axis.
AssemblyTwo to eight cores laid parallel in one plane between films.
Reinforcement FillerOptional - material not specified.
JacketExtruded PVC, 9 mils min average thickness, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.