APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5365 Issued:1999-09-16
Revised:2012-04-26
Style 5365 Laminated flat ribbon cable.

Rating80 deg C, 60 Vac, Horizontal flame.
Conductor40 AWG - 12 AWG flat or round, solid or stranded.
InsulationPOLYIMIDE or PPS, 0.4 mils minimum. (1) polyphenylene sulfide (PPS) film bonded each side with 0.5 mil polyester adhesive. (2) polyimide film bonded on each side with 0.4 mils polyester adhesive. Total combined thickness shall be 0.8 mils minimum. 10 mils minimum edge width and 3 mils minimum between conductors.
AssemblyOne to 150 conductors laid straight or irregular parallel in one plane.
ShieldOptional - Optional metal faced polymeric tape.
CoveringOptional.
Misc.Optional - Drain wire.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024