Rating | 450 deg C, 600 Vac, Horizontal Flame. |
|
Conductor | 22 AWG - 4/0 AWG, Solid or Stranded Round, in sizes 22-8 AWG; larger sizes stranded only. |
|
Insulation | Extruded Mica covered by a Non-Extruded Fiberglass Braid |
| Conductor AWG Size | mils minimum average | mils minimum at any point |
| 22-12 | 28 | 25 |
| 11-4 | 37 | 33 |
| 3-4/0 | 47 | 42 |
|
Assembly | Optional, two or more conductors described above, may be cabled together with a max O.D. of 1.500 inches. A mica glass binder and/or fiberglass fillers may be employed. The assembly has an overall treated glass braid. |
|
Shield | Optional. 36-30 AWG Type "A" Nickel or 27% minimum nickel coated copper. |
|
Braid | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|