APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5377 Issued:2000-10-19
Revised:2012-05-16
Style 5377 Single or Multiple Conductor Cable with Extruded Insulation and Non-Extruded Covering

Rating450 deg C, 600 Vac, Horizontal Flame.
Conductor22 AWG - 4/0 AWG, Solid or Stranded Round, in sizes 22-8 AWG; larger sizes stranded only.
InsulationExtruded Mica covered by a Non-Extruded Fiberglass Braid
Conductor AWG Sizemils minimum averagemils minimum at any point
22-122825
11-43733
3-4/04742
AssemblyOptional, two or more conductors described above, may be cabled together with a max O.D. of 1.500 inches. A mica glass binder and/or fiberglass fillers may be employed. The assembly has an overall treated glass braid.
ShieldOptional. 36-30 AWG Type "A" Nickel or 27% minimum nickel coated copper.
BraidOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025