APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5402 Issued:2003-02-19
Revised:2012-05-02
Style 5402 Single conductor with other-than extruded insulation

Rating200 deg C, 1000 Vac, Horizontal flame.
Conductor30 AWG - 20 AWG solid or stranded round.
InsulationPolyimide tape, 5.5 mils min average, 5 mils minimum at any point.
CoveringExtruded FEP, 0.5 mils minimum average, 0.4 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring, such as Sensor Cable.

UL and the UL Logo are trademarks of UL LLC © 2024