Rating | 80 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 50 AWG - 4/0 AWG Flat. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Multiconductor Laminated Flat Cable with Extruded Insulated Conductors. Two or more singles twisted pairs, or groups of twisted singles or pairs are laid parallel to form a flat cable. Barrier layer and/or fillers optional. Laminated with one layer of expanded PTFE tape 4 mils minimum average thickness and 3 mils minimum thickness at any point and one layer of polyurethane tape 11 mils minimum average thickness and 9 mils minimum thickness at any point. Then applied with optional shield. |
|
Shield | Optional. Between the labeled insulated conductors and the laminated layers. May be over insulated conductors or groups of conductors. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|