Rating | 60 deg C, voltage rating not applicable, VW-1 flame. |
|
Fiber Optic | Glass fiber coated with urethane acrylate, 11 mils maximum diameter. |
|
Misc. | Reinforcement Filler - Optional, material not specified. |
|
Subunit Jacket | Extruded FRPE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
Strength Members | Solid steel wire, approx. 26 AWG, two employed. |
|
Assembly | One or two sub-units laid parallel, solid steel strength wires embedded in outer jacket in one plane with sub-units. Each sub-unit consists of one optic core, reinforcement filler and sub-unit jacket. |
|
Jacket | Extruded FRPE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring or External Interconnection of Electronic Equipment. Steel wires or any other metal or electrically conductive parts in the cable are not intended for current carrying or signal transmission purpose. |
|