APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5410 Issued:2003-12-18
Revised:2012-11-12
Style 5410 Multiple-conductor cable using non-integral jacket

Rating75 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles and/or twisted pairs, and optical fiber members cabled around the strength member. Strength member consists of the stranded galvanized steel with 12 mils minimum thickness PE covering. A barrier layer and/or fillers are optional.
ShieldCopper braid, applied over the assembly.
JacketExtruded PVC/TPU.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.275 inch or less40 mils32 mils
0.276-0.425 inch50 mils40 mils
0.426-0.700 inch60 mils48 mils
Outer JacketOptional, same as Jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring. Centrally located steel strands wire is a strength member and not for current carrying purpose, it shall be connected to Ground at both ends.

UL and the UL Logo are trademarks of UL LLC © 2024