Rating | 350 deg C, 300 Vac, Horizontal flame. |
|
Conductor | Five strands, each strand 5 mils diameter. The conductor is wound spirally with at least 14 turns per inch on a glass fiber core. The conductor assembly, the conductor and the fiber core, 58 mils outside diameter |
|
Insulation | Fiberglass Braid, 45 mils minimum average thickness, 41 mils minimum thickness at any point, 4 strands, 6.2 mils diameter strands, 14 picks per inch. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring, Resistance Heater Wire. |
|