APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5419 Issued:2003-12-18
Revised:2011-11-22
Style 5419 Single conductor with other than extruded insulation.

Rating350 deg C, 300 Vac, Horizontal flame.
ConductorFive strands, each strand 5 mils diameter. The conductor is wound spirally with at least 14 turns per inch on a glass fiber core. The conductor assembly, the conductor and the fiber core, 58 mils outside diameter
InsulationFiberglass Braid, 45 mils minimum average thickness, 41 mils minimum thickness at any point, 4 strands, 6.2 mils diameter strands, 14 picks per inch.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring, Resistance Heater Wire.

UL and the UL Logo are trademarks of UL LLC © 2024