APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5423 Issued:2004-12-23
Revised:2012-07-10
Style 5423 Laminated flat Cable.

Rating75 deg C, 30 Vac, Horizontal flame.
Conductor28 AWG - 27 AWG Flat, Tinned Plated Annealed Copper.
InsulationNon-extruded Polyester FILM/TAPE, 3 mils min average. May be stripped approximately 157 mil intervals throughout the cable length.
AssemblyFour Parallel Flat Conductors. 35 mils apart.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.