APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5424 Issued:2005-03-25
Revised:2012-12-12
Style 5424 Single conductor with other-than-extruded insulation

Rating550 deg C, 300 Vac, Horizontal Flame.
Conductor24 AWG - 4 AWG, solid or stranded.
InsulationMica composite and fiberglass braid treated with SR varnish or PTFE finish.
Conductor sizeMinimum average thickness of Mica compositeMinimum average thickness of fiberglass braid
24-12 AWG15 mils11 mils
11-4 AWG24 mils15 mils
ShieldOptional. Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subject to movement after installation.

UL and the UL Logo are trademarks of UL LLC © 2024