APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5437 Issued:2007-08-31
Revised:2012-03-15
Style 5437 Single Conductor with Other-Than-Extruded Insulation

Rating250 deg C, 300 Vac, Horizontal flame.
Conductor50 AWG - 29 AWG, one or more wires wound spirally around a glass fiber core.
Insulation
Inner Insulation: Glass fiber wrap with four layers. Each successive layer wound in reverse direction
Outer Insulation: Glass fiber braid covered with silicone varnish
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring installed where not subject to movement or mechanical abuse.