APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5443 Issued:2008-04-16
Revised:2012-01-17
Style 5443 Laminated Flat Ribbon Cable

Rating105 deg C, 30 Vac, Horizontal flame.
ConductorNo. 40-12 AWG, flat or round conductors.
Insulation0.3 mil min PETP film with 0.9 mil min polyester adhesive and 0.3 mil min polyimide film (PI) with 0.5 mil min polyester adhesive on each side of conductors laminated together. 5 mils minimum edge width and 3 mils minimum between conductors.
Assembly2-150, Straight or irregular parallel in one plane.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024