APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5444 Issued:2008-04-21
Revised:2012-05-02
Style 5444 Single conductor with other-than-extruded insulation and covering

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 16 AWG min. solid or stranded.
InsulationInner: Foamed PTFE tape, overall thickness 2 mils minimum average, 1 mil minimum at any point, applied with minimum 20 percent overlap and heat-sealed. Outer: Polyester tape, overall thickness 0.2 mil minimum at any point, applied with minimum 20 percent overlap and heat-sealed with polyester adhesive.
ShieldRequired.
CoveringPolyester tape, overall thickness 1 mil minimum at any point, applied with minimum 25 percent overlap and heat sealed with polyester adhesive.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.