APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5453 Issued:2009-03-27
Revised:2012-07-10
Style 5453 Laminated Flat Cable

Rating80 deg C, 60 Vac, Horizontal flame.
Conductor40 - 12 AWG min. Flat, bare, tinned, nickel or gold coated copper.
Insulation0.5 mil min. Non-extruded PETP film with 0.4 mil min. PE adhesive. 3 mils minimum edge width and 5 mils minimum distance between conductors.
Assembly2-100 conductors, laid straight or irregular parallel in one plane to form a flat cable. A shield, metal clad PETP film with polyeseter adhesive on metal side, wraps insulation with an overlap.
ShieldMin. 0.5 mil thick metal clad PETP film with an overlap min. 0.15 inch.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024